X10 PHASE COUPLER / SIGNAL BRIDGE

Are you having troublecontrollingsome of your X10 devices from a particular location, but can controlit from other locations?

Are someX10 devicesintermittent?

More than likely, the problem modules and your controller are on opposite phases of your house wiring and need to be electrically coupled.

TRY THIS SIMPLE TEST: Turn on any 220 volt appliance (dryer, range, air conditioner) NOTE: If you don\'t have active 220 volt appliances to test, move the module or the controller so they are both plugged into the same circuit (on the same breaker or fuse). If the module(s) now consistently respond to commands, THIS PHASE COUPLER SHOULD FIX THE PROBLEM

  • PROVIDESOPTIMUM COUPLING OF X10 SIGNALS
  • RATED AT 630VDC (250VAC) MORE THAN ENOUGH TO SAFELY HANDLE 220VAC
  • EASY INSTALLATION
  • Made by ISO 9002 & 9001 certified manufacturer
  • Most houses are fed from a 220 volt service which is then split into two phases of 110 volts each in the circuit breaker box (see fig. 1 above). The X10 signals, which are transmitted onto the house wiring on one phase, will normally travel across to the other phase through the breaker panel, pole transformer, etc. If however, the data transmission is not making it from one phase of house wiring to the other, you may couple the signal between them by installing this phase coupler acrossthe two phases in the panel, i.e. by connecting the coupler across your 220V air conditioner breaker or any 220V 30Amp Max. breaker. Breakers feeding heat producing appliances such as water heater, range, dryer or devices that draw high current on startup should not be used. The excessive heat that builds up at the breaker terminals from these devices will eventually cause heat failure of the coupler. Alternatively, you can install the coupler between two adjacent 120V breakers if they are on different phases (see fig. 2 above).

    MODULE COUPLING OF X10 SIGNALS

  • RATED FOR UP TO 630VDC (250 VAC)SERVICE MORE THAN ENOUGH CAPACITY TO SAFELY HANDLE 220 VAC
  • EASY INSTALLATION
  • I\'VE USED THIS METHOD OF SOLVING X10 MODULE PROBLEMS SUCCESSFULLYFOR OVER 30 YEARS

    INSTALLATION IS SIMPLE (BE SURE TO SAFELY SHUT POWER TO THE WORK OFF)

    IF YOU\'RE UNCERTAIN HOW TO INSTALL THESE, CONSULT A KNOWLEDGEABLE FRIEND OR QUALIFIED ELECTRICIAN

    IF YOUR MODULES STILL DON\'T WORK PROPERLY AND RELIABLY WHEN YOU TRY THE SIMPLE TEST ABOVE, YOU MAY ALSO HAVE LINE NOISE.CLICK HERE TO SEE IF A NOISE FILTER MAY HELP SOLVE YOUR PROBLEM.

    • SHIPPING TO US BUYERS ONLY $2.50

    PLEASE ASK ANY QUESTIONS BEFORE BUYING

    READ WHAT THESE BUYERS HAD TO SAY ABOUT THIS ITEM:

    Your couplers are such a fantastic bargain I think everyone should try one before putting out big cash for the commercial coupler and repeater boxes. You\'re doing a great service to the X-10 community!

    Fantastic! Absolutely the FASTEST shipping ever!!! Unbelievable! :-)

    FAST DELIVERY ; GOOD PRODUCT; AN EXCELLENT ER

    Everything as advertised and if an opportunity arises will offer again

    Got it quick, looks great! Thanks.

    excellent er -great communication-fast shipping-helpful -A+++

    Very helpful, courteous, and professional. Thank You!

    Item exactly as described. Easy transaction. A+++ seller

    Item as described and shipped very quickly. Thanks!

    Recieved installed and works, Thanks excellent er

    Great Fix for X10 problems Thanks! Fast Shipping AAA+++ Seller!!

    Thanks, Worked Well!!!

    Good service. Wish I had known there was such an item before.

    CLICK HERE TO SEE MORE X10 DEVICES

    DON\'TSEE WHAT YOU WANT? NEED LARGER QUANTITIES? Contact me with your zip code andemail address with your requirements

    WHENEVER POSSIBLE, I COMBINE ACTUAL WEIGHT ON MULTIPLE ITEM PURCHASES AND CHARGE ACTUAL SHIPPING & HANDLING CHARGES

    THANK YOU FOR LOOKING AND GOOD LUCK !!

    Be sure to add me to your favorites list!

    Sign up for my email newsletters by adding my store to your Favorites

    Visit My store: Big John\'s Place


    On Oct-17-08 at 08:38:08 PDT, seller added the following information:

    Installation on breakers controlling high heat devices such as water heaters, ranges, dryers ordevices that draw high current on startup should not be used. These breakers typically build up heat at their terminals which could transfer to the coupler, causing heat failure.An air conditioner breaker is the ideal location.

    On Feb-15-10 at 15:56:24 PST, seller added the following information:

    NOTE TO INTERNATIONAL BUYERS: UNLESS OTHERWISE SPECIFIED, THE X10 PRODUCTS ON THE U.S. SITE USE 120V 60HZ POWER. WIRELESS DEVICES OPERATE ON THE U.S. FREQUENCY OF 310MHZPRICE AND SHIPPING DOES NOT INCLUDE ANY CUSTOMS FEES, DUTIES OR TAXES WHICH ARE THE RESPONSIBILITY OF THE BUYER



    .

    Buy Now


    Other Related Items:



    Related Items:Search: X10+Phase

    Telco Systems LC-7124-2XFP-B Plug-In Line Card 2x10G XFP Ports, Sync Phase Clock picture

    Telco Systems LC-7124-2XFP-B Plug-In Line Card 2x10G XFP Ports, Sync Phase Clock

    $800.00



    Vinyl Laptop Computer Skin Sticker Decal Wrap 10 inch to 17 inch 15 Wrap HQ Gift picture

    Vinyl Laptop Computer Skin Sticker Decal Wrap 10 inch to 17 inch 15 Wrap HQ Gift

    $15.95



    Telco Systems LC-7124-2XFP-B 2x10GE XFP SYNC CLOCK PHASE CLOCK quantity  picture

    Telco Systems LC-7124-2XFP-B 2x10GE XFP SYNC CLOCK PHASE CLOCK quantity

    $455.20