New Eaton 9155 8000VA K4081100BBJX000 UPS Backup 9155-8 Warranty New
Brand New!Product snapshotPOWER RATING
8-15 kVA at 0.9 power factor
VOLTAGE
200-240 VAC with neutral or with optional input transformer
FREQUENCY
50/60 Hz
TOPOLOGY
Double conversion
CONFIGURATION
Compact tower
UPS model specs
MODELS
(8-15 KVA)
DIMENSIONS
(H x W x D, INCHES)
WEIGHT
(LBS)
9155, 2-high with (1) battery module32.2 x 12 x 33.73529155, 3-high with (2) battery module47.8 x 12 x 33.75909155, 3-high with (1) battery module and (1) transformer module47.8 x 12 x 33.7558Full tech (VA/WATTS)Up to 15000/13500DIAGNOSTICSFull system self-test at startupUPS BYPASSAutomatic on overload or UPS failureWARRANTYTwo-year factory warrantyCONTENTS (SHIPS WITH THE FOLLOWING ITEMS)1 ready-to-go UPS, software suite CD, user guideEFFICIENCYUp to 91%ELECTRICAL INPUTCONNECTIONHardwired - see manual for terminal block layoutFREQUENCY50/60 Hz (45 to 65 Hz)FREQUENCY RANGE45 to 65 HzINPUT POWER FACTORP.F >0.99 typical, >0.96 frequency converterGENERATOR COMPATABILITYYesELECTRICAL OUTPUTOUTPUT VOLTAGE100/200, 110/220, 120/240 Vac 180° phase displacement; 120/208, 127/220 Vac 120° phase displacementOUTPUT RECEPTACLES(1) PDMON UTILITY VOLTAGE REGULATIONOutput voltage regulation ±1% Static; ±5% dynamic at 100% resistive load changeON BATTERY VOLTAGE REGULATIONOutput voltage regulation ±1% Static; ±5% dynamic at 100% resistive load changeOVERLOAD CAPACITY150% for 5 sec / 125% for 1 min (online), 110% for 10 minVOLTAGE WAVE SHAPE (ON BATTERY)Sine WaveTRANSFER TIME0 msBATTERYBATTERY MANAGEMENTABM technologyBATTERY TYPE9Ah, sealed, lead-acid, maintenance-freeBATTERY REPLACEMENTField-replaceableSTART ON BATTERYAllows start of UPS without utility inputRECHARGE TIMEInternal battery: approximately 3 hours to 80% usable capacity at nominal line voltage after full load discharge External battery: no more than 10x discharge time to 90% usable capacity at nominal line voltage after full load dischargeCOMMUNICATIONSUSER INTERFACELCD Display with blue backlightLEDS(4) LEDs for notice and alarmAUDIBLE ALARMSYesCOMMUNICATION PORTS(1) RS-232, (1) relay contact, (1) REPO, (2) environmental inputCOMMUNICATION SLOT(2) X-Slot communication baysPOWER MANAGEMENT SOFTWAREBundled Software Suite CDENVIRONMENTAL & STANDARDSAUDIBLE NOISE<53dBA at 1 meter (noise less room) typicalOPERATING TEMPERATURE10°C to +40°C, +45°C with 7.5% derating; Batteries recommended max. +25°CSTORAGE TEMPERATURE-15°C to +25°CRELATIVE HUMIDITY0-95%, non condensingCERTIFICATIONSSAFETY CERTIFICATIONSUL1778 5thEdition, CSA C22.2 No. 107.3-14, NOM-NYCEEMC COMPLIANCE47 CFR Part 15/ICES-003 Class AQUALITYISO 9001:2015, ISO 14001:2004SURGEANSI C62.41 Category B3, IEC 61000-4-5MARKINGScULus, NOM-NYCE