UBB Store

Eaton Powerware PW9130L2000R-XL2U 2000VA 1800W Double Conversion Online UPS -...
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.
Eaton Powerware PW9130L2000R-XL2U 2000VA 1800W Double Conversion Online UPS -...
Price: US $999.99

Manufacturer: Eaton Powerware
Model: Eaton Powerware 9130 2000VA 1800W Rackmount 2U, 20A, 120V
Condition: New Batteries, Refurbished UPS
Part Number: PW9130L2000R-XL2U
Maximum Output: 1800W / 2000VA
Typical Backup Time at Half Load: 26 Minutes (900W)
Typical Backup Time at Full Load: 9 Minutes (1800W)
Input: NEMA 5-20P, 120V
Output: (6) NEMA 5-20R, (1) NEMA L5-20R
Topology: Double-Conversion Online
Output Waveform: Pure Sine Wave
Form Factor: Rackmount 2U
Extended Runtime: Yes – Supports up to (4) External Battery Modules
Replacement Battery: EBP-1607
Network Management: Optional Network Card-MS / Network Card-M2 
Warranty: 1 Year Full Replacement Warranty

Description: The Eaton Powerware 9130 PW9130L2000R-XL2U is a 2000VA / 1800W double-conversion online UPS designed for servers, networking equipment, telecommunications systems, and other critical IT applications. It operates at 120V with a NEMA 5-20P input and provides (6) NEMA 5-20R and (1) NEMA L5-20R output receptacles. Eaton's official rear-panel diagram confirms this exact outlet configuration for the PW9130L2000R-XL2U

 

 


Eaton Powerware 9130 2000VA 1800W PW9130L2000R-XL2U - User - Eaton Powerware 9130 2000VA Powerware Product FamilyEaton 9130 ModelPW9130L2000R-XL2U Product TypeUninterruptible Power Supply (UPS) Rated Power1800W / 2000VA Power Factor0.9 Main Input Voltage120V AC Main Output Voltage120V AC PhaseSingle Phase TopologyOnline Double-Conversion Output WaveformPure Sine Wave ConfigurationRackmount Rack Height2U Extended RuntimeYes DiagnosticsFull System Self-Test UPS BypassAutomatic Bypass High-Efficiency ModeYes Efficiency – High-Efficiency Mode>95% Efficiency – Online Mode>86% Cold StartSupported    Input  Input ConnectionNEMA 5-20PNominal Input Voltage120V AC Selectable Input Voltages100V / 110V / 120V / 127V AC Nominal Input Current16.7A Circuit / Breaker Rating20A Input Voltage Range at 100% Load90–144V AC Nominal Frequency50/60Hz Auto-Sensing Input Frequency Range40–70Hz Before Transfer to Battery Bypass Voltage Range+10% / -15% of Nominal, Default Input Cord Length6 ft Input Noise FilteringMOVs for Normal and Common Mode Noise    Output  Output Capacity2000VA / 1800W Rated Output Power1800W Rated Output Apparent Power2000VA Nominal Output Voltage120V AC Selectable Output Voltages100V / 110V / 120V / 127V AC Output Voltage Regulation – Online±3% of Nominal Output Voltage Regulation – Battery±3% of Nominal Output Frequency50/60Hz Frequency Regulation±3Hz Online Output WaveformPure Sine Wave Load Crest Factor3:1 Output Power Factor0.9 Total Output Receptacles(7) NEMA 5-20R Receptacles(6)NEMA L5-20R Receptacles(1)Rear Panel Outlet Configuration(6) NEMA 5-20R + (1) NEMA L5-20R Output Load Segments(2) Controllable Load Segments Individual Outlet SwitchingNo – Control is by Load Segment Controllable Output ReceptaclesYes – Grouped into Controllable Load Segments Load Segment ControlIndependently Configurable Programmable Load ShutdownYes Programmable Load StartupYes Load SequencingYes Load SheddingYes Automatic BypassYes    Voltage Regulation  Online Voltage Regulation±3% of Nominal Battery Voltage Regulation±3% of Nominal Selectable Nominal Voltage100V / 110V / 120V / 127V Frequency IndependenceYes – Online Double-Conversion Operation Generator CompatibilityYes High-Efficiency Operating ModeSelectable    Batteries & Runtime  Battery TypeSealed Lead-Acid Internal Battery Configuration(6) 12V, 9Ah Batteries Internal Battery Voltage72VDC Battery ManagementEaton ABM Technology Hot-Swappable Internal BatteriesYes Hot-Swappable External BatteriesYes Replacement BatteryEBP-1607 Typical Runtime at Half Load26 Minutes at 900W Typical Runtime at Full Load9 Minutes at 1800W Internal Battery Recharge TimeApproximately 3 Hours to 90% Cold Start / Start on BatteryYes Start Without Utility PowerSupported Automatic Battery TestingYes Battery Health MonitoringYes Low Battery WarningYes Extended RuntimeYes Compatible Rackmount EBMPW9130N3000R-EBM2U EBM Voltage72VDC EBM ApplicationEaton 9130 Rackmount 2000–3000VA UPS Models Maximum Number of EBMs(4) Battery / EBM ConnectorExternal Three-Pole Anderson Connector Recharge Time – Internal Batteries3 Hours Recharge Time – (1) EBM9 Hours Recharge Time – (2) EBMs15 Hours Recharge Time – (3) EBMs21 Hours Recharge Time – (4) EBMs27 Hours EBM Compatibility VerificationPW9130N3000R-EBM2U, 72VDC, specified for 2000–3000VA rackmount models Maximum EBM SupportUp to (4) EBMs per UPS    Power Management Features  Online Double-ConversionYes High-Efficiency ModeYes Automatic BypassYes Cold StartYes Load Segment ManagementYes Number of Load Segments(2) Independent Load Segment ControlYes Load Segment On / Off ControlYes Delayed Load Segment StartupConfigurable Delayed Load Segment ShutdownConfigurable Automatic RestartConfigurable Load SheddingSupported Battery TestAutomatic / Manual Full System Self-TestYes Firmware UpgradeableYes Generator CompatibilityYes    Communications & Management  Communication Bay(1) Available Communication Bay Network Management Card IncludedNo Network ManagementOptional Compatible Network CardEaton Network Card-MS / Network Card-M2 / Relay Interface Card Relay Interface Card SupportYes RS-232 Port(1) DB9 RS-232 Communication Speed1200–9600 bps USB Port(1) USB Communication Speed9600 bps Relay OutputYes Relay Output Contacts(1) Three-Pole Connector with (1) Contact Closure Programmable Signal Inputs(4) Signal Input FunctionBuilding Alarms or Other Programmable External Signals Remote UPS MonitoringSupported with Compatible Communication Card / Software Remote ShutdownSupported UPS Status MonitoringYes Load MonitoringYes Battery MonitoringYes Runtime MonitoringYes Alarm MonitoringYes Power Management SoftwareEaton Power Management Software Communication Options VerificationCommunication bay, Network Card-MS, Network Card-M2, Relay Interface Card, RS-232, USB, programmable signal inputs and relay output contacts    User Interface, Alerts & Controls  User InterfaceGraphical LCD LCD BacklightBlue Status LEDs(4) Status-Indicating LEDs Display Language – EnglishSupported Display Language – FrenchSupported Display Language – GermanSupported Display Language – RussianSupported Display Language – SpanishSupported UPS Status DisplayYes Load InformationYes Battery InformationYes Runtime InformationYes Alarm InformationYes Operating Mode InformationYes Event LogYes Audible AlarmYes Control PanelLCD with Navigation / Control Buttons    Emergency Power Off & Control Terminals  Remote Emergency Power-OffYes REPO PortYes Emergency Shutdown ControlSupported through REPO Port Forced Bypass ControlSupported Relay Output ContactsYes Programmable Signal FactorRackmount Rack Height2U Rack CompatibilityStandard 19-Inch Rack Installation OrientationHorizontal Rackmount Only Height3.4 in (86.5 mm) Width17.2 in (438 mm) Depth23.6 in (600 mm) Net Weight63.9 lb (29.0 kg) Rail KitRackmount Rail Hardware Supported Rail Adjustment Range24–30 in (61–76 cm) Front-to-Rear Rack Depth Physical Specifications Verification3.4 × 17.2 × 23.6 in; 63.9 lb / 29.0 kg    Environmental  Operating Temperature0°C to 40°C (32°F to 104°F) Operating Mode Temperature0°C to 40°C in Online Mode Altitude DeratingLinear Derating for Altitude Overtemperature ProtectionTransfers Load to Bypass in Case of Overheating Storage Temperature with Batteries-20°C to +40°C (-4°F to 104°F) Storage Temperature without Batteries-25°C to +55°C (-13°F to 131°F) Relative Humidity5–90%, Non-Condensing Audible Noise<50 dBA Heat Dissipation – Line838 BTU/h Heat Dissipation – Battery1348 BTU/h Installation EnvironmentIndoor, Temperature and Humidity Controlled Maximum Recommended Ambient Temperature40°C (104°F)    Surge Protection & Filtering  Power ConditioningContinuous Online Double-Conversion Input Noise FilteringMetal Oxide Varistors (MOVs) Noise Filtering ModesNormal Mode and Common Mode Power Failure ProtectionYes Power Sag ProtectionYes Power Surge ProtectionYes Brownout ProtectionYes Line Noise ProtectionYes High Voltage Spike ProtectionYes Frequency Variation ProtectionYes Switching Transient ProtectionYes Harmonic Distortion ProtectionYes Power Disturbance ProtectionEaton specifies protection against these common power problems    General Features  True Online Double-ConversionYes Utility Frequency IndependenceYes Generator CompatibleYes Advanced Battery ManagementABM Technology High-Efficiency ModeSelectable Extended Runtime CapabilityUp to (4) EBMs Firmware UpgradeableYes Remote Emergency ShutdownREPO Standard CommunicationRS-232, USB and Relay Output Contacts Optional Connectivity CardsSupported Eaton 9130 Feature VerificationEaton specifies online double-conversion, ABM, high-efficiency mode, 2U rackmount design, RS-232, USB, relay contacts, optional connectivity cards, up to four EBMs and REPO    Conformance  RoHS ComplianceYes Safety MarkingsUL, cUL, VCCI EMC MarkingsFCC Class A, EN55022 Class A FCC ClassificationClass A Digital Device    Condition & Warranty  UPS ConditionRefurbished Battery ConditionNew Batteries Warranty1 Year Full Replacement Warranty 

Buy Now